Water volume → flow → equipment checks
Pool Pump Size Calculator
Start with your water volume. Get a circulation target, then check head and equipment limits.
Last updated 15 October 2026
Local calculation · no signup
Calculate circulation flow
Measurements first. Sources and unknowns stay with the answer.
Your result will appear here
Enter your measurements and choose Calculate. Blank physical inputs do not produce a precomputed answer.
Still unknown or unconfirmed
Resolve the unknown fit checks before choosing equipment.
Compare exact-model pump choicesInputs and units used
Formula, sources and blank printable worksheet
CIRC-1: required GPM = US gallons / (selected hours × 60). Actual fit needs complete head/curve and device checks.
Calculation version 1.0 uses historical engineering references for arithmetic, not current residential law.
- Sta-Rite Engineering and Design Manual, second edition, 2003, printed pp. 2, 27, 29, 36-40, 44 https://www.pentair.com/content/dam/extranet/nam/pentair-pool/residential/manuals/training/Sta-Rite%20Engineering%20and%20Design%20Manual.pdf
- NIST Handbook 44, Appendix C: US gallon and length units https://www.nist.gov/system/files/documents/2019/11/19/00-20-hb44-final11152019pdf.pdf
- DOE / Hydraulic Institute, Improving Pumping System Performance, second edition https://www.energy.gov/sites/default/files/2014/05/f16/pump.pdf
- Archived SuperFlo VS guide, printed p. 19: approximate 3000 RPM reference curve, 115/230V https://flowandfiltrationsolutions.pentair.com/content/dam/extranet/nam/pentair-pool/residential/pumps/archive/superflo-vs/manuals/superflovs-variable-speed-pump-manual-english.pdf
| Quantity / unit | Reading | Source and date |
|---|---|---|
| Water volume | ________________ | ________________ |
| Volume unit | ________________ | ________________ |
| Circulation scenario: hours per equivalent volume | ________________ | ________________ |
| Circuit context | ________________ | ________________ |
| Documented TDH, feet | ________________ | ________________ |
| Actual flow for head measurement, US GPM | ________________ | ________________ |
| Head source / measurement date | ________________ | ________________ |
| Pump-adjacent discharge psi | ________________ | ________________ |
| Suction reading (positive value for vacuum) | ________________ | ________________ |
| Suction reading unit | ________________ | ________________ |
| Taps at same elevation and equal pipe bore? | ________________ | ________________ |
| Each active device: model, minimum / maximum GPM and manual | ________________ | ________________ |
| Exact pump curve: model, revision, voltage, RPM and source | ________________ | ________________ |
| Actual flow at head, source tolerance and unresolved limits | ________________ | ________________ |
Mark missing measurements Unknown. Keep exact model, source revision and assumptions with this worksheet. Report a calculation or source correction with reproducible inputs.

This pool pump size calculator starts with the flow needed for your chosen period. It keeps that target apart from head and actual flow. It checks known device limits too. Gallons alone cannot tell you which horsepower to buy.
Divide US gallons by hours × 60 to get required gallons per minute. Check that flow against the devices that must run together. The pump must supply it at the circuit's head. Head is energy per unit weight, shown here in feet of water.
If head or a device rating is unknown, fit stays unconfirmed. The worked example shows maths. It is not a pump choice for your pool.
Pool pump size calculator: start with circulation flow
Enter known water volume or use the volume tool. Choose a circulation period deliberately. The 6-, 8- and 12-hour options are scenarios, not universal residential rules. They do not promise clear or safe water.
For 15,000 US gallons and an illustrative 8-hour period, required flow is 15,000 ÷ 480 = 31.25 GPM. That equals about 118.294 litres per minute or 7.09765 cubic metres per hour. The arithmetic follows the Sta-Rite engineering manual, printed page 40. Its historic public-pool rules are not used here as current residential requirements.
Check the flow each device needs
Record the exact filter, heater, chlorinator and cleaner that will operate in the same period. Use the minimum and maximum flow in each device's own manual. A device that is absent is different from a device whose rating is unknown.
Required flow is at least the circulation target or the largest known device minimum, whichever is higher. The allowed upper limit is the smallest known device maximum. If required flow is above that limit, the devices conflict. A larger pump cannot fix the conflict.
For example, an artificial 40 GPM heater minimum and 35 GPM accessory maximum cannot both be met in the same series circuit. Separate modes may need a different documented arrangement. The calculator does not design that arrangement or approve a bypass.
Pool pump size calculator head methods
Head describes the energy the pump adds per unit weight of water. It is not just the pump's height above the pool. In a full path back to the same pool, do not add that height again as a fixed static lift. The DOE pumping sourcebook explains static head and friction head. It also explains pump and system curves.
Choose a documented design head, a proper pump-adjacent gauge measurement or a simple series-pipe estimate. A head measured at one flow belongs to that flow. It cannot be held fixed while predicting every new operating point.
Gauge measurements
For equal-height taps with the same pipe bore, the simplified estimate is discharge psi × 2.31 plus positive suction vacuum in inches of mercury × 1.13. The signs matter: a vacuum is below atmospheric pressure. A filter gauge alone does not supply both sides of the pump.
At 20 psi discharge and 10 inHg suction vacuum, this gives 57.5 feet. The historical manual rounds its example to 57 feet. Different tap heights or pipe speeds need elevation and velocity corrections. Record them or leave the full head unknown.
Series-pipe estimate
Enter each suction and return section separately. Nominal Schedule 40 pipe size is not its inside diameter. The reference bores for nominal 1.5, 2, 2.5 and 3 inches are 1.61, 2.067, 2.469 and 3.068 inches.
Use documented equivalent lengths or loss coefficients for fittings. Add equipment pressure-loss curves at the same trial flow. Unknown fittings or equipment losses do not count as zero. Parallel branches and water features are outside this simple solver.
As a source check, 50 GPM through 100 feet of straight 2-inch Schedule 40 PVC gives about 4 feet of friction head. That is the pipe-only row on printed page 29 of the engineering manual. It is not a complete pool-circuit estimate.
Check a pump curve at its actual operating point
A maker's curve ties flow to head for an exact pump. Speed and voltage conditions matter too. Enter sourced points and name the source.
The calculator can find where this curve meets a complete system-loss curve. It works only within the supplied range. It does not extend curves past the source data.
A curve above the required flow/head point suggests available capacity. It does not prove the actual operating flow or whole-system fit. The actual intersection can be at a greater flow that exceeds a filter or heater limit. Check limits at that operating flow too.
The archived SuperFlo VS graph, printed page 19 is a labelled reference example. At 3,000 RPM, 60 GPM is near 46 feet of head, with about 2 feet/2 GPM reading tolerance. It does not describe a current SuperFlo VST. At 2,200 RPM, that archived curve's shutoff head is about 33 feet, so it cannot meet a 40-foot duty.
Why horsepower cannot finish the selection
Horsepower is not a flow rating. Two pumps with the same horsepower label can have different curves. The circuit, speed, voltage, filter condition and active devices affect the operating point. Use actual-flow measurements rather than an unsupported gallons-to-HP chart.
The RPM scenario tool shows corresponding affinity estimates for one pump and impeller. It does not turn an arbitrary speed into exact circuit flow. The filter tool checks a documented filter rating separately.
Print a useful sizing record
Keep the volume and units with your chosen hours. List each active device and the head method. Save the source curves and unknowns too. The print sheet records calculation version 1.0 and the check date.
You can download JSON for a local record. Browser saving is optional. Choose it to save inputs, or clear them when done.
No contact details are needed for a calculation. A result with missing head or ratings remains a circulation target with incomplete fit checks. It should not acquire a precise equipment verdict just because the arithmetic produced decimals.
Related measurements and operation
Use runtime to invert measured flow into hours. Use electricity use after measuring input watts. Heating uses a different load: the heater calculator separates useful heat, purchased energy and losses.
If the pump will not establish water flow, follow the priming guide before measuring duty. A faulty or air-filled circuit is not a sound baseline for selecting replacement equipment.
FAQ
Is one turnover enough to make water safe?
The equation counts an equivalent volume moved. It does not track each bit of water. It cannot prove filter performance or water quality. It cannot show that enough disinfectant reached the pool. Device instructions still apply. Keep the purpose of your chosen period with the saved result.
What happens if head is unknown?
You still get the required flow from volume and time. The calculator labels head unknown. It does not give a precise pump-fit result. Gather a suitable reading or a complete source-based circuit estimate. Do not fill the gap with a fixed allowance that has no source for your pool.
Verdict on pool pump sizing
Use the pool pump size calculator to establish required flow and expose the checks still needed. Confirm actual duty against the exact curve and every active device. The formulas follow Pentair engineering references, DOE pump-system guidance and NIST units. Report a source or calculation issue.
Compare equipment after checking your duty
Use your flow, head and device limits to rule out a mismatch. Each comparison keeps exact models and unresolved checks beside the choice.
3 Variable Speed Pool Pump Choices in 2026Compare local controls, exact model codes and duty checks for three variable-speed pool pumps, with tools for flow and energy.
4 Best Variable Speed Pool Pump Choices in 2026Compare four variable-speed pumps through exact-model duty, controls, energy, installation scope and warranty checks.
4 Best Pool Pump Choices in 2026Compare four pool-pump candidates by replacement task, control needs, supply and required flow, with clear limits on each pick.
3 Energy Efficient Pool Pump Choices in 2026Compare three variable-speed pool pumps, then check exact-model efficiency, flow at head and measured energy before choosing.
3 Hayward Variable Speed Pool Pump Choices in 2026Compare exact MaxFlo, Super Pump and TriStar W3 models, keeping voltage, curves, controls and efficiency records separate.
Pentair Variable Speed Pool Pump: EC-342001 in 2026Review the SuperFlo EC-342001 and check Pentair's model suffixes, drive revisions, controls and online sales terms before buying.
3 Best Above Ground Pool Pump Choices in 2026Compare a two-speed replacement, a 220V variable-speed pump and a sand-filter package with their fit limits kept visible.
3 Best Above Ground Pool Pump and Filter Combo Choices in 2026Compare three INTEX sand-filter packages by exact model, rated system flow, tank size and pool-side connections.
AQUASTRONG Pool Pump Reviews: PSP300PM in 2026Review the AQUASTRONG PSP300PM's published controls, supply and performance limits, with clear distinctions from smaller family models.
3 Digital Pool Pump Timer Choices in 2026Compare an outdoor Wi-Fi timer, a replacement mechanism and an indoor control by enclosure, motor load and pump interface.